Recently, a comment on our social media post attracted my attention. It was a question of European buyers of solar energy storage systems who accidentally purchased a three-phase 380V hybrid inverter instead of the single-phase 230V model they needed, causing their system to fail. We have proposed our solution, and the inverter now is running smoothly.

The Fix:

We installed an AC distribution box between the inverter and the load, allowing the three-phase inverter to power multiple single-phase loads. Here’s how it works:

Connect the three-phase inverter to the circuit breaker (A) via the UPS port.

Link the circuit breaker (A) to three circuit breakers (B) using four busbars:                     

    L1 → L1, L2 → L2, L3 → L3, the neutral wires from the breakers (B) are combined and connected to the neutral wire of the breaker (A).

Connect three breakers (B) to the home loads separately.

Key Notes:

1. Each single-phase load must not exceed 6kW, and the total load must stay within the inverter’s capacity.

2. This solution works for systems under 20kW.

3. A three-phase inverter can power single-phase loads, but a single-phase inverter cannot support three-phase loads.

 

Facing a similar issue or technical headaches? Don’t worry—contact us for expert advice and solutions!

 

Contact now:
Business Consulting: Karen Wang

Mobile/Whatsapp/Wechat:  +86 189 0569 0996  /  Email:  info@ue-pv.com  

 

 Technical Consulting: Simon Peng 

Mobile/Whatsapp/Wechat:  +86 186 1698 9760  /  Email:  simon@ue-pv.com

اترك رسالة

اترك رسالة
إذا كنت مهتمًا وترغب في معرفة المزيد من التفاصيل ، فالرجاء ترك رسالة هنا ، وسنرد عليك في أقرب وقت ممكن.
Submit

Home

products

whatsApp

contact